The Hydro-Pure®
series deionizers offered two stages both co-flow and counter-flow deionizers
for the applications in different industrial process. These systems are
available in a versatile range of outputs from 1.0 m3/hr to 90 m3/hr.
The co-flow (HTS) range is developed to produce a cost-effective supply of good
quality deionized water to meet a wide spectrum of customer needs. Particular
emphasis has been placed on ease of operation, maintenance and service, plus
features which enable users to easily check how the unit is performing.
The counter-flow (HCI) system is
adopting an improved technique, which better water quality can be produced by
these units. By using HCI system, a higher working capacity can be obtained from
the ion exchange resin for a given regeneration level. Waste water is minimized,
and the reduced volume of volume of water required during the regeneration
cycle, together with the use of smaller effluent neutralization facilities,
result in cost savings.
The range of Hydro-pure deionizers
are skid mounted packaged units which are pressure tested and semi-commissioned
before delivery. This considerably reduces installation time and the overall
capital cost of plant.
|
Features
|
Benefits |
Option |
-
Designed for cost-effectiveness and
efficiency in ion exchange.
-
Skid mounted Packaged Plant.
-
Co-flow or counter-flow regeneration
-
Simultaneous regeneration
Fully or semi-automatic.
|
-
Competitive capital & running cost.
-
Low installation cost and time.
-
Higher quality water or lower costs
on different requirement.
-
Cut down the outage time and less
storage space is required.
-
Reduced operator involvement.
|
|
Technical Data for Co-Flow Demineralizer (HTS)
|
Deioniser |
Flowrate |
Capacity |
Regenerant |
Plumbing |
Space requirement |
Work |
|
Models |
Min. |
Max. |
Max. |
HCl 33% |
NaOH 48% |
Inlet |
Outlet |
Width |
Depth |
Height |
Weight |
|
Manual |
Automatic |
m3/hr |
m3/hr |
Kg as CaCO3 |
Lits. |
Lits. |
mm |
mm |
mm |
mm |
mm |
Kg |
|
HTS250M |
HTS250A |
0.2 |
1.5 |
0.9 |
6 |
3.3 |
20 |
20 |
2500 |
600 |
2000 |
390 |
|
HTS300M |
HTS300A |
0.3 |
2.0 |
1.6 |
10 |
5.5 |
20 |
20 |
2500 |
600 |
2000 |
400 |
|
HTS400M |
HTS400A |
0.8 |
3.2 |
3.8 |
20 |
11 |
25 |
25 |
2700 |
700 |
2000 |
500 |
|
HTS500M |
HTS500A |
1.4 |
6.0 |
6.9 |
35 |
19 |
40 |
40 |
3400 |
800 |
2000 |
880 |
|
HTS600M |
HTS600A |
2.4 |
9.0 |
11.5 |
59 |
32 |
40 |
40 |
4000 |
900 |
3000 |
1200 |
|
HTS750M |
HTS750A |
4.0 |
15.0 |
19.0 |
98 |
54 |
50 |
50 |
4500 |
1100 |
3000 |
2085 |
|
HTS900M |
HTS900A |
5.6 |
22.0 |
26.5 |
137 |
75 |
50 |
50 |
4700 |
1200 |
3000 |
2590 |
|
HTS1100M |
HTS1100A |
7.0 |
30.0 |
50.2 |
260 |
143 |
50 |
50 |
5200 |
1500 |
3000 |
3330 |
Technical Data for Counter-Flow
Demineralizer (HCI)
|
Deioniser |
Flowrate |
Capacity |
Regenerant |
Plumbing |
Space requirement |
Work |
|
Models |
Min. |
Max. |
Max. |
HCl 33% |
NaOH 48% |
Inlet |
Outlet |
Width |
Depth |
Height |
Weight |
|
Manual |
Automatic |
m3/hr |
m3/hr |
Kg as CaCO3 |
Lits. |
Lits. |
mm |
mm |
mm |
mm |
mm |
Kg |
|
N/A |
HCI250 |
0.2 |
1.5 |
0.9 |
6 |
3.3 |
20 |
20 |
2500 |
600 |
2000 |
390 |
|
N/A |
HCI300 |
0.3 |
2.0 |
1.6 |
10 |
5.5 |
20 |
20 |
2500 |
600 |
2000 |
400 |
|
N/A |
HCI400 |
0.8 |
4.0 |
3.8 |
20 |
11 |
25 |
25 |
2700 |
700 |
2000 |
500 |
|
N/A |
HCI500 |
1.4 |
6.0 |
6.9 |
34 |
18.5 |
40 |
40 |
3400 |
800 |
2000 |
880 |
|
N/A |
HCI600 |
2.4 |
10.0 |
11.5 |
51 |
28 |
40 |
40 |
4000 |
900 |
3000 |
1200 |
|
N/A |
HCI750 |
4.0 |
15.0 |
19.0 |
83 |
47 |
50 |
50 |
4500 |
1100 |
3000 |
2085 |
|
N/A |
HCI900 |
5.6 |
20.0 |
26.5 |
114 |
64 |
50 |
50 |
4700 |
1200 |
3000 |
2590 |
|
N/A |
HCI1100 |
7.0 |
27.0 |
50.2 |
234 |
129 |
50 |
50 |
5200 |
1500 |
3000 |
3330 |
|
N/A |
HSC3500 |
30.0 |
35.0 |
16.0 |
70 |
42 |
80 |
80 |
2390 |
1550 |
2790 |
2500 |
|
N/A |
HSC5000 |
45.0 |
50.0 |
23.0 |
103 |
61 |
80 |
80 |
2390 |
1550 |
2840 |
2600 |
|
N/A |
HSC7000 |
60.0 |
70.0 |
32.0 |
142 |
84 |
100 |
100 |
2960 |
1730 |
2870 |
3100 |
|
N/A |
HSC9000 |
80.0 |
90.0 |
42.5 |
189 |
112 |
100 |
100 |
2960 |
1730 |
2940 |
3200 |
|
Specification
|
Client to Provide |
|
Treated water quality |
Conductivity
(micro S/cm) |
Silica
(ppm) |
-
Power supply for automatic models 240
VAC / 415 VAC , 50 Hz
-
Air supply at 5 -7 bar, 6-10 l/m
intermittent
-
Raw water, treated water and drain
pipework to and from the unit
-
Booster / pressure reducing system if
pressure not within the range
|
|
TS |
<10 |
0.2 |
|
HCI |
2 av. |
0.2 |
|
HSC |
2 av. |
0.2 |
|
Vessel |
FRP with Vinylester lining
|
|
Controller |
PLC
|
|
Pipework |
PVC
|
|