Nước là sự sống

Water Deionizer - HYDRO-PURE® 

 

The Hydro-Pure®  series deionizers offered two stages both co-flow and counter-flow deionizers for the applications in different industrial process. These systems are available in a versatile range of outputs from 1.0 m3/hr to 90 m3/hr. 

The co-flow (HTS) range is developed to produce a cost-effective supply of good quality deionized water to meet a wide spectrum of customer needs. Particular emphasis has been placed on ease of operation, maintenance and service, plus features which enable users to easily check how the unit is performing.
 

The counter-flow (HCI) system is adopting an improved technique, which better water quality can be produced by these units. By using HCI system, a higher working capacity can be obtained from the ion exchange resin for a given regeneration level. Waste water is minimized, and the reduced volume of volume of water required during the regeneration cycle, together with the use of smaller effluent neutralization facilities, result in cost savings.

 

The range of Hydro-pure deionizers are skid mounted packaged units which are pressure tested and semi-commissioned before delivery. This considerably reduces installation time and the overall capital cost of plant.

 

Features

Benefits

Option

  • Designed for cost-effectiveness and efficiency in ion exchange.
     

  • Skid mounted Packaged Plant.
     

  • Co-flow or counter-flow regeneration
     

  • Simultaneous regeneration
    Fully or semi-automatic.
     

  • Competitive capital & running cost.
     

  • Low installation cost and time.
     

  • Higher quality water or lower costs on different requirement. 
     

  • Cut down the outage time and less storage space is required.
     

  • Reduced operator involvement.

  • Pre and post treatment.
     

  • Duplex configuration.
     

  • Effluent pH correction. 
     

  • Sequential regeneration.
     

  • Manual and mixed bed unit.
     

 

Technical Data for Co-Flow Demineralizer (HTS) 

 

Deioniser

  Flowrate

Capacity

 Regenerant

 Plumbing

Space requirement

  Work

Models

Min.

Max.

Max.

HCl 33%

NaOH 48%

Inlet

Outlet

Width

Depth

Height

Weight

Manual

Automatic

m3/hr

m3/hr

Kg as CaCO3

Lits.

Lits.

mm

mm

mm

mm

mm

Kg

HTS250M

HTS250A

0.2

1.5

0.9

6

3.3

20

20

2500

600

2000

390

HTS300M

HTS300A

0.3

2.0

1.6

10

5.5

20

20

2500

600

2000

400

HTS400M

HTS400A

0.8

3.2

3.8

20

11

25

25

2700

700

2000

500

HTS500M

HTS500A

1.4

6.0

6.9

35

19

40

40

3400

800

2000

880

HTS600M

HTS600A

2.4

9.0

11.5

59

32

40

40

4000

900

3000

1200

HTS750M

HTS750A

4.0

15.0

19.0

98

54

50

50

4500

1100

3000

2085

HTS900M

HTS900A

5.6

22.0

26.5

137

75

50

50

4700

1200

3000

2590

HTS1100M

HTS1100A

7.0

30.0

50.2

260

143

50

50

5200

1500

3000

3330

 

Technical Data for Counter-Flow Demineralizer (HCI) 

 

Deioniser

 Flowrate

Capacity

  Regenerant

 Plumbing

Space requirement

 Work

 Models

Min.

Max.

Max.

HCl 33%

NaOH 48%

Inlet

Outlet

Width

Depth

Height

Weight

Manual

Automatic

m3/hr

m3/hr

Kg as CaCO3

Lits.

Lits.

mm

mm

mm

mm

mm

Kg

N/A

HCI250

0.2

1.5

0.9

6

3.3

20

20

2500

600

2000

390

N/A

HCI300

0.3

2.0

1.6

10

5.5

20

20

2500

600

2000

400

N/A

HCI400

0.8

4.0

3.8

20

11

25

25

2700

700

2000

500

N/A

HCI500

1.4

6.0

6.9

34

18.5

40

40

3400

800

2000

880

N/A

HCI600

2.4

10.0

11.5

51

28

40

40

4000

900

3000

1200

N/A

HCI750

4.0

15.0

19.0

83

47

50

50

4500

1100

3000

2085

N/A

HCI900

5.6

20.0

26.5

114

64

50

50

4700

1200

3000

2590

N/A

HCI1100

7.0

27.0

50.2

234

129

50

50

5200

1500

3000

3330

N/A

HSC3500

30.0

35.0

16.0

70

42

80

80

2390

1550

2790

2500

N/A

HSC5000

45.0

50.0

23.0

103

61

80

80

2390

1550

2840

2600

N/A

HSC7000

60.0

70.0

32.0

142

84

100

100

2960

1730

2870

3100

N/A

HSC9000

80.0

90.0

42.5

189

112

100

100

2960

1730

2940

3200

 

 Specification

 Client to Provide

Treated water quality

Conductivity

(micro S/cm)

Silica

(ppm)

  • Power supply for automatic models 240 VAC / 415 VAC , 50 Hz
     

  • Air supply at 5 -7 bar, 6-10 l/m intermittent

  • Raw water, treated water and drain pipework to and from the unit
     

  • Booster / pressure reducing system if pressure not within the range

TS

<10

0.2

HCI

2 av.

0.2

HSC

2 av.

0.2

Vessel

FRP with Vinylester lining

 

Controller

PLC

 

Pipework

PVC